InovaPrint - Cleaning Denture Base Resin Workflow

Modified on Thu, 11 Jul at 4:45 PM

  1. Place the appliance in a rigid plastic or glass container and cover with Inova Print Wash
  2. Place the container in an ultrasonic device with enough water to match the level of solvent in the container
  3. Run ultrasonic for 2 min. with no heat
  4. Remove the appliance, rinse with water, and dry with an air syringe. 
  5. Check for residual surface resin. f any exists, place the appliance in a second container with 99% IPA and place it into ultrasonic for 1 min.
  6. Remove and dry well with an air syringe.